Network Working Group N. Brownlee
Request for Comments: 2064 The University of Auckland
Category: Experimental January 1997
Traffic Flow Measurement: Meter MIB
Status of this Memo
This memo defines an Experimental Protocol for the Internet
community. This memo does not specify an Internet standard of any
kind. Discussion and suggestions for improvement are requested.
Distribution of this memo is unlimited.
Abstract
This memo defines a portion of the Management Information Base (MIB)
for use with network management protocols in TCP/IP-based internets.
In particular, this memo defines managed objects used for obtaining
traffic flow information from network traffic meters.
Table of Contents
1 The Network Management Framework . . . . . . . . . . . . . . . . 1
2 Objects . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.1 Format of Definitions . . . . . . . . . . . . . . . . . . . 3
3 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.1 Scope of Definitions, Textual Conventions . . . . . . . . . 3
3.2 Usage of the MIB variables . . . . . . . . . . . . . . . . 4
4 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5 Acknowledgements . . . . . . . . . . . . . . . . . . . . . . . . 37
6 References . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
7 Security Considerations . . . . . . . . . . . . . . . . . . . . 38
8 Author's Address . . . . . . . . . . . . . . . . . . . . . . . . 38
1 The Network Management Framework
The Internet-standard Network Management Framework consists of three
components. They are:
RFC 1155 defines the SMI, the mechanisms used for describing and
naming objects for the purpose of management. STD 16, RFC 1212
defines a more concise description mechanism, which is wholly
consistent with the SMI.
Brownlee Experimental [Page 1]
RFC 2064 Meter MIB January 1997
RFC 1156 defines MIB-I, the core set of managed objects for the
Internet suite of protocols. STD 17, RFC 1213 [1] defines MIB-II,
an evolution of MIB-I based on implementation experience and new
operational requirements.
STD 15, RFC 1157 defines the SNMP, the protocol used for network
access to managed objects.
RFC 1442 [2] defines the SMI for version 2 of the Simple Network
Management Protocol.
RFCs 1443 and 1444 [3,4] define Textual Conventions and
Conformance Statements for version 2 of the Simple Network
Management Protocol.
RFC 1452 [5] describes how versions 1 and 2 of the Simple Network
Management Protocol should coexist.
The Framework permits new objects to be defined for the purpose of
experimentation and evaluation.
2 Objects
Managed objects are accessed via a virtual information store, termed
the Management Information Base or MIB. Objects in the MIB are
defined using the subset of Abstract Syntax Notation One (ASN.1) [6]
defined in the SMI. In particular, each object has a name, a syntax,
and an encoding. The name is an object identifier, an
administratively assigned name, which specifies an object type. The
object type together with an object instance serves to uniquely
identify a specific instantiation of the object. For human
convenience, we often use a textual string, termed the OBJECT
DESCRIPTOR, to also refer to the object type.
The syntax of an object type defines the abstract data structure
corresponding to that object type. The ASN.1 language is used for
this purpose. However, the SMI [2] purposely restricts the ASN.1
constructs which may be used. These restrictions are explicitly made
for simplicity.
The encoding of an object type is simply how that object type is
represented using the object type's syntax. Implicitly tied to the
notion of an object type's syntax and encoding is how the object type
is represented when being transmitted on the network.
The SMI specifies the use of the basic encoding rules of ASN.1 [7],
subject to the additional requirements imposed by the SNMP.
Brownlee Experimental [Page 2]
RFC 2064 Meter MIB January 1997
2.1 Format of Definitions
Section 4 contains contains the specification of all object types
contained in this MIB module. These object types are defined using
the conventions defined in [2] and [3].
3 Overview
Traffic Flow Measurement seeks to provide a well-defined method for
gathering traffic flow information from networks and internetworks.
The background for this is given in "Traffic Flow Measurement:
Background" [8]. The Realtime Traffic Flow Measurement (rtfm)
Working Group has produced a measurement architecture to achieve it;
this is documented in "Traffic Flow Measurement: Architecture" [9].
The architecture defines three entities:
- METERS, which observe network traffic flows and build up a
table of flow data records for them,
- METER REAERS, which collect traffic flow data from meters, and
- MANAGERS, which oversee the operation of meters and meter readers.
This memo defines the SNMP management information for a Traffic Flow
Meter (TFM). It documents the earlier work of the Internet Accounting
Working Group, and is intended to provide a starting point for the
Realtime Traffic Flow Measurement Working Group.
3.1 Scope of Definitions, Textual Conventions
All objects defined in this memo are registered in a single subtree
within the mib-2 namespace [1,2], and are for use in network devices
which may perform a PDU forwarding or monitoring function. For these
devices, the value of the ifSpecific variable in the MIB-II [1] has
the OBJECT IDENTIFIER value:
flowMIB OBJECT IDENTIFIER ::= mib-2 40
as defined below.
The RTFM Meter MIB was first produced and tested using SNMPv1. It
has been converted into SNMPv2 following the guidelines in RFC 1452
[5].
Brownlee Experimental [Page 3]
RFC 2064 Meter MIB January 1997
3.2 Usage of the MIB variables
The MIB breaks into four parts - control, flows, rules and
conformance statements.
The rules implement the minumum set of packet-matching actions, as
set out in the "Traffic Flow Measurment: Architecture" document [9].
In addition they provide for BASIC-style subroutines, allowing a
network manager to dramatically reduce the number of rules required
to monitor a big network.
Traffic flows are identified by a set of attributes for each of its
end-points. Attributes include network addresses for each layer of
the network protocol stack, and 'subscriber ids,' which may be used
to identify an accountable entity for the flow.
The conformance statements are set out as defined in [4]. They
explain what must be implemented in a meter which claims to conform
to this MIB.
To retrieve flow data one could simply do a linear scan of the flow
table. This would certainly work, but would require a lot of
protocol exchanges. To reduce the overhead in retrieving flow data
the flow table uses a TimeFilter variable, defined as a Textual
Convention in the RMON2 MIB [10]. This, when used together with
SNMPv2's GetBulk request, allows a meter reader to scan the flow
table and upload a specified set of flow attributes for those rows
which have changed since the last reading.
As an alternative method of reading flow data, the MIB provides an
index into the flow table called flowColumnActivityTable. This is
(logically) a three-dimensional array, subscripted by flow attribute,
activity time and starting flow number. This allows a meter reader
to retrieve (in an opaque object) data for a column of the flow table
with a minimum of SNMP overhead. An attempt has been made to include
a full ASN.1 definition of the flowColumnActivityData object.
One aspect of data collection which needs emphasis is that all the
MIB variables are set up to allow multiple independent colletors to
work properly, i.e. the flow table indexes are stateless. An
alternative approach would have been to 'snapshot' the flow table,
which would mean that the meter readers would have to be
synchronized. The stateless approach does mean that two meter
readers will never return exactly the same set of traffic counts, but
over long periods (e.g. 15-minute collections over a day) the
discrepancies are acceptable. If one really needs a snapshot, this
can be achieved by switching to an identical rule set with a
different RuleSet number, hence asynchronous collections may be
Brownlee Experimental [Page 4]
RFC 2064 Meter MIB January 1997
regarded as a useful generalisation of synchronised ones.
The control variables are the minimum set required for a meter
reader. Their number has been whittled down as experience has been
gained with the MIB implementation. A few of them are 'general,'
i.e. they control the overall behaviour of the meter. These are set
by a single 'master' manager, and no other manager should attempt to
change their values. The decision as to which manager is the
'master' must be made by the network operations personnel
responsible; this MIB does not attempt to provide any support for
interaction between managers.
There are three other groups of control groups, arranged into tables
in the same way as in the RMON MIB [10]. They are used as follows:
- RULE SET INFO: Before attempting to download a rule table a manager
must create a row in the flowRuleSetInfo with flowRuleInfoStatus
set to 'createAndWait.' When the rule set is ready the manager
must set RuleSetInfo to 'active,' indicating that the rule set is
ready for use.
- METER READER INFO: Any meter reader wishing to collect data
reliably for all flows should first create a row in the
flowReaderInfoTable with flowReaderStatus set to 'active.' It
should write that row's flowReaderLastTime object each time it
starts a collection pass through the flow table. The meter will
not recover a flow's memory until every meter reader holding a row
in this table has collected that flow's data.
- MANAGER INFO: Any manager wishing to download rule sets to the
meter must create a row in the flowManagerInfo table with
flowManagerStatus set to 'active.'. Once it has a table row, the
manager may set the control variables in its row so as to cause the
meter to run any valid rule set held by the meter.
Brownlee Experimental [Page 5]
RFC 2064 Meter MIB January 1997
4 Definitions
FLOW-METER-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Counter32, Integer32, TimeTicks
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, RowStatus, TimeStamp
FROM SNMPv2-TC
OBJECT-GROUP, MODULE-COMPLIANCE
FROM SNMPv2-CONF
mib-2, ifIndex
FROM RFC1213-MIB
OwnerString
FROM RMON-MIB;
flowMIB MODULE-IDENTITY
LAST-UPDATED "9603080208Z"
ORGANIZATION "IETF Realtime Traffic Flow Measurement Working Group"
CONTACT-INFO
"Nevil Brownlee, The University of Auckland
Email: n.brownlee@auckland.ac.nz"
DESCRIPTION
"MIB for the RTFM Traffic Flow Meter."
::= { mib-2 40 }
flowControl OBJECT IDENTIFIER ::= { flowMIB 1 }
flowData OBJECT IDENTIFIER ::= { flowMIB 2 }
flowRules OBJECT IDENTIFIER ::= { flowMIB 3 }
flowMIBConformance OBJECT IDENTIFIER ::= { flowMIB 4 }
-- Textual Conventions
TimeFilter ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Used as an index to a table. A TimeFilter variable allows
a GetNext or GetBulk request to find rows in a table for
which the TimeFilter index variable is greater than or equal
to a specified value. For example, a meter reader could
find all rows in the flow table which have been active at or
since a specified time.
Brownlee Experimental [Page 6]
RFC 2064 Meter MIB January 1997
More details on TimeFilter variables, their implementation
and use can be found in the RMON2 MIB [10]."
SYNTAX TimeTicks
AddressType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Indicates the type of an adjacent address or peer address.
The values used are from the 'Address Family Numbers' section
of the Assigned Numbers RFC [11]."
SYNTAX INTEGER {
ip(1),
nsap(3),
ieee802(6),
ipx(11),
appletalk(12),
decnet(13) }
AdjacentAddress ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Specifies the value of an adjacent address for various
media. The values used for IEEE 802 media are from the
'Network Management Parameters (ifType definitions)'
section of the Assigned Numbers RFC [11]. Address format
depends on the actual media, as follows:
Ethernet: ethernet(7)
6-octet 802.3 MAC address in 'canonical' order
FDDI: fddi(15)
FddiMACLongAddress, i.e. a 6-octet MAC address
in 'canonical' order (defined in the FDDI MIB [12])
Token Ring: tokenring(9)
6-octet 802.5 MAC address in 'canonical' order
PeerAddress: other(1)
If traffic is being metered inside a tunnel, its
adjacent addresses will be the peer addresses of hosts
at the ends of the tunnel
"
SYNTAX OCTET STRING (SIZE (6..20))
PeerAddress ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Specifies the value of a peer address for various network
Brownlee Experimental [Page 7]
RFC 2064 Meter MIB January 1997
protocols. Address format depends on the actual protocol,
as follows:
IP: ip(1)
4-octet IpAddress (defined in the SNMPv2 SMI [2])
CLNS: nsap(3)
NsapAddress (defined in the SNMPv2 SMI [2])
Novell: ipx(11)
4-octet Network number,
6-octet Host number (MAC address)
AppleTalk: appletalk(12)
2-octet Network number (sixteen bits),
1-octet Host number (eight bits)
DECnet: decnet(13)
1-octet Area number (in low-order six bits),
2-octet Host number (in low-order ten bits)
"
SYNTAX OCTET STRING (SIZE (3..20))
TransportAddress ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Specifies the value of a transport address for various
network protocols. Format as follows:
IP:
2-octet UDP or TCP port number
Other protocols:
2-octet port number
"
SYNTAX OCTET STRING (SIZE (2))
RuleAddress ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Specifies the value of an address. Is a superset of
AdjacentAddress, PeerAddress and TransportAddress."
SYNTAX OCTET STRING (SIZE (2..20))
FlowAttributeNumber ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Uniquely identifies an attribute within a flow data record."
Brownlee Experimental [Page 8]
RFC 2064 Meter MIB January 1997
SYNTAX INTEGER {
flowIndex(1),
flowStatus(2),
flowTimeMark(3),
sourceInterface(4),
sourceAdjacentType(5),
sourceAdjacentAddress(6),
sourceAdjacentMask(7),
sourcePeerType(8),
sourcePeerAddress(9),
sourcePeerMask(10),
sourceTransType(11),
sourceTransAddress(12),
sourceTransMask(13),
destInterface(14),
destAdjacentType(15),
destAdjacentAddress(16),
destAdjacentMask(17),
destPeerType(18),
destPeerAddress(19),
destPeerMask(20),
destTransType(21),
destTransAddress(22),
destTransMask(23),
pduScale(234),
octetScale(25),
ruleSet(26),
toOctets(27), -- Source-to-Dest
toPDUs(28),
fromOctets(29), -- Dest-to-Source
fromPDUs(30),
firstTime(31), -- Activity times
lastActiveTime(32),
sourceSubscriberID(33), -- Subscriber ID
destSubscriberID(34),
sessionID(35),
sourceClass(36), -- Computed attributes
destClass(37),
flowClass(38),
sourceKind(39),
destKind(40),
flowKind(41) }
Brownlee Experimental [Page 9]
RFC 2064 Meter MIB January 1997
RuleAttributeNumber ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Uniquely identifies an attribute which may be tested in
a rule. These include attributes whose values come directly
from the flow's packets and the five 'meter' variables used to
hold an AttributeValue. Attributes derived from the rules -
e.g. address masks - may not be tested."
SYNTAX INTEGER {
null(0),
sourceInterface(4), -- Source Address
sourceAdjacentType(5),
sourceAdjacentAddress(6),
sourcePeerType(8),
sourcePeerAddress(9),
sourceTransType(11),
sourceTransAddress(12),
destInterface(14), -- Dest Address
destAdjacentType(15),
destAdjacentAddress(16),
destPeerType(18),
destPeerAddress(19),
destTransType(21),
destTransAddress(22),
sourceSubscriberID(33), -- Subscriber ID
destSubscriberID(34),
sessionID(35),
v1(51), -- Meter variables
v2(52),
v3(53),
v4(54),
v5(55) }
ActionNumber ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Uniquely identifies the action of a rule, i.e. the Pattern
Matching Engine's opcode number. Details of the opcodes
are given in the 'Traffic Flow Measurement: Architecture'
document [9]."
SYNTAX INTEGER {
ignore(1),
fail(2),
count(3),
countPkt(4),
return(5),
gosub(6),
gosubAct(7),
Brownlee Experimental [Page 10]
RFC 2064 Meter MIB January 1997
assign(8),
assignAct(9),
goto(10),
gotoAct(11),
pushRuleTo(12),
pushRuleToAct(13),
pushPktTo(14),
pushPktToAct(15) }
--
-- Control Group: Rule Set Info Table
--
flowRuleSetInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF FlowRuleSetInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An array of information about the rule sets held in the
meter. Rule set 1 is the meter default, used when the meter
starts up. It is built in to the meter; it may not be
changed."
::= { flowControl 1 }
flowRuleSetInfoEntry OBJECT-TYPE
SYNTAX FlowRuleSetInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular rule set."
INDEX { flowRuleInfoIndex }
::= { flowRuleSetInfoTable 1 }
FlowRuleSetInfoEntry ::= SEQUENCE {
flowRuleInfoIndex Integer32,
flowRuleInfoSize Integer32,
flowRuleInfoOwner OwnerString,
flowRuleInfoTimeStamp TimeStamp,
flowRuleInfoStatus RowStatus
}
flowRuleInfoIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index which selects an entry in the flowRuleSetInfoTable.
Brownlee Experimental [Page 11]
RFC 2064 Meter MIB January 1997
Each such entry contains control information for a particular
rule set which the meter may run."
::= { flowRuleSetInfoEntry 1 }
flowRuleInfoSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Number of rules in this rule set. Setting this variable will
cause the meter to allocate space for these rules."
::= { flowRuleSetInfoEntry 2 }
flowRuleInfoOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Identifies the manager which configured this rule set."
::= { flowRuleSetInfoEntry 3 }
flowRuleInfoTimeStamp OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Time this rule set was last changed."
::= { flowRuleSetInfoEntry 4 }
flowRuleInfoStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this rule set. If this object's value is
not active(1), the meter must not attempt to use this
rule set."
::= { flowRuleSetInfoEntry 5 }
--
-- Control Group: Interface Info Table
--
flowInterfaceTable OBJECT-TYPE
SYNTAX SEQUENCE OF FlowInterfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
Brownlee Experimental [Page 12]
RFC 2064 Meter MIB January 1997
"An array of information specific to each meter interface."
::= { flowControl 2 }
flowInterfaceEntry OBJECT-TYPE
SYNTAX FlowInterfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular interface."
INDEX { ifIndex }
::= { flowInterfaceTable 1 }
FlowInterfaceEntry ::= SEQUENCE {
flowInterfaceRate Integer32,
flowInterfaceLostPackets Counter32
}
flowInterfaceRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The parameter N for statistical counting on this interface.
Set to N to count 1/Nth of the packets appearing at this
interface. A meter should choose its own algorithm to
introduce variance into the sampling so that exactly every Nth
packet is not counted. A sampling rate of 1 counts all
packets. A sampling rate of 0 results in the interface
being ignored by the meter."
::= { flowInterfaceEntry 1 }
flowInterfaceLostPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets the meter has lost for this interface.
Such losses may occur because the meter has been unable to
keep up with the traffic volume."
::= { flowInterfaceEntry 2 }
--
-- Control Group: Meter Reader Info Table
--
-- Any meter reader wishing to collect data reliably for all flows
-- should first create a row in this table. It should write that
-- row's flowReaderLastTime object each time it starts a collection
Brownlee Experimental [Page 13]
RFC 2064 Meter MIB January 1997
-- pass through the flow table.
-- The meter will not recover a flow's memory until every meter reader
-- holding a row in this table has collected that flow's data.
-- If a meter reader does not create a row in this table, e.g. because
-- it failed authentication in the meter's SNMP write community,
-- collection can still proceed but the meter may not be able to
-- recover inactive flows.
flowReaderInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF FlowReaderInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An array of information about meter readers which have
registered their intent to collect flow data from this meter."
::= { flowControl 3 }
flowReaderInfoEntry OBJECT-TYPE
SYNTAX FlowReaderInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular meter reader."
INDEX { flowReaderIndex }
::= { flowReaderInfoTable 1 }
FlowReaderInfoEntry ::= SEQUENCE {
flowReaderIndex Integer32,
flowReaderTimeout Integer32,
flowReaderOwner OwnerString,
flowReaderLastTime TimeStamp,
flowReaderPreviousTime TimeStamp,
flowReaderStatus RowStatus
}
flowReaderIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Selects an entry from the array of meter reader info entries."
::= { flowReaderInfoEntry 1 }
flowReaderTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
Brownlee Experimental [Page 14]
RFC 2064 Meter MIB January 1997
STATUS current
DESCRIPTION
"Specifies the maximum time (in seconds) between flow data
collections for this meter reader. If this time elapses
without a collection, the meter should assume that this meter
reader has stopped collecting, and delete this row from the
table."
::= { flowReaderInfoEntry 2 }
flowReaderOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Identifies the meter reader which created this row."
::= { flowReaderInfoEntry 3 }
flowReaderLastTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Time this meter reader began its most recent data collection.
This variable should be written by a meter reader as the first
step in reading flow data. The meter will set this LastTime
value to sysUptime and set its PreviousTime value (below) to
the old LastTime. This allows the meter to recover flows
which have been inactive since PreviousTime, for these have
been collected at least once.
If the meter fails to write flowLastReadTime, e.g. by
failing authentication in the meter's SNMP write community,
collection may still proceed but the meter may not be able to
recover inactive flows."
::= { flowReaderInfoEntry 4 }
flowReaderPreviousTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time this meter reader began the collection before last."
::= { flowReaderInfoEntry 5 }
flowReaderStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
Brownlee Experimental [Page 15]
RFC 2064 Meter MIB January 1997
STATUS current
DESCRIPTION
"The status of this meter reader."
::= { flowReaderInfoEntry 6 }
--
-- Control Group: Manager Info Table
--
-- Any manager wishing to download rule sets to the meter must create
-- a row in this table. Once it has a table row, the manager may set
-- the control variables in its row so as to cause the meter to run
-- any valid rule set held by the meter.
flowManagerInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF FlowManagerInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An array of information about managers which have
registered their intent to run rule sets on this meter."
::= { flowControl 4 }
flowManagerInfoEntry OBJECT-TYPE
SYNTAX FlowManagerInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular meter reader."
INDEX { flowManagerIndex }
::= { flowManagerInfoTable 1 }
FlowManagerInfoEntry ::= SEQUENCE {
flowManagerIndex Integer32,
flowManagerCurrentRuleSet Integer32,
flowManagerStandbyRuleSet Integer32,
flowManagerHighWaterMark INTEGER,
flowManagerCounterWrap INTEGER,
flowManagerOwner OwnerString,
flowManagerTimeStamp TimeStamp,
flowManagerStatus RowStatus
}
flowManagerIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
Brownlee Experimental [Page 16]
RFC 2064 Meter MIB January 1997
"Selects an entry from the array of manager info entries."
::= { flowManagerInfoEntry 1 }
flowManagerCurrentRuleSet OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Index to the array of rule sets. Specifies which set of
rules is currently being used for accounting by this manager.
When the manager sets this variable the meter will close its
current rule set and start using the new one. Flows created
by the old rule set remain in memory, orphaned until their
data has been read. Specifying rule set 0 (the empty set)
stops flow measurement by this manager."
::= { flowManagerInfoEntry 2 }
flowManagerStandbyRuleSet OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Index to the array of rule sets. After reaching
HighWaterMark (see below) the manager may switch to using its
standby rule set. For this to be effective the manager should
have downloaded a standby rule set which uses a coarser
reporting granularity. The manager may also need to
decrease the meter reading interval so that the meter can
recover flows measured by its normal rule set."
DEFVAL { 0 } -- No standby
::= { flowManagerInfoEntry 3 }
flowManagerHighWaterMark OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A value expressed as a percentage, interpreted by the meter
as an indication of how full the flow table should be before
it should switch to the standby rule set (if one has been
specified) forthis manager. Values of 0% or 100% disable
the checking represented by this variable."
::= { flowManagerInfoEntry 4 }
flowManagerCounterWrap OBJECT-TYPE
SYNTAX INTEGER { wrap(1), scale(2) }
MAX-ACCESS read-create
STATUS current
Brownlee Experimental [Page 17]
RFC 2064 Meter MIB January 1997
DESCRIPTION
"Specifies whether PDU and octet counters should wrap when
they reach the top of their range (normal behaviour for
Counter32 objects), or whether their scale factors should
be used instead. The combination of counter and scale
factor allows counts to be returned as binary floating
point numbers, with 32-bit mantissas and 8-bit exponents."
DEFVAL { wrap }
::= { flowManagerInfoEntry 5 }
flowManagerOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Identifies the manager which created this row."
::= { flowManagerInfoEntry 6 }
flowManagerTimeStamp OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Time this row was last changed by its manager."
::= { flowManagerInfoEntry 7 }
flowManagerStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this manager."
::= { flowManagerInfoEntry 8 }
--
-- Control Group: General Meter Control Variables
--
-- At present the meter only runs a single rule set - the 'current'
-- one and has a single 'standby' rule set. In future it may be
-- developed so as to run multiple rule sets simultaneously; that would
-- require a more elaborate set of control variables to allow reliable
-- operation.
flowFloodMark OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-write
STATUS current
Brownlee Experimental [Page 18]
RFC 2064 Meter MIB January 1997
DESCRIPTION
"A value expressed as a percentage, interpreted by the meter
as an indication of how full the flow table should be before
it should take some action to avoid running out of resources
to handle new flows. Values of 0% or 100% disable the
checking represented by this variable."
::= { flowControl 5 }
flowInactivityTimeout OBJECT-TYPE
SYNTAX Integer32 (1..3600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time in seconds since the last packet seen, after
which the flow may be terminated. Note that although a
flow may have been terminated, its data must be collected
before its memory can be recovered."
DEFVAL { 600 } -- 10 minutes
::= { flowControl 6 }
flowActiveFlows OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The numbers of flows which are currently in use, i.e. have
been active since the last collection."
::= { flowControl 7 }
flowMaxFlows OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of flows allowed in the meter's
flow table. At present this is determined when the meter
is first started up."
::= { flowControl 8 }
--
-- The Flow Table
--
-- This is a table kept by a meter, with one flow data entry for every
-- flow being measured. Each flow data entry stores the attribute
-- values for a traffic flow. Details of flows and their attributes
-- are given in the 'Traffic Flow Measurement: Architecture'
Brownlee Experimental [Page 19]
RFC 2064 Meter MIB January 1997
-- document [9].
-- From time to time a meter reader may sweep the flow table so as
-- to read counts. This is most effectively achieved by using the
-- TimeMark variable together with successive GetBulk requests to
-- retrieve the values of the desired flow attribute variables.
-- This scheme allows multiple meter readers to independently use the
-- same meter; the meter readers do not have to be synchronised and
-- they may use different collection intervals.
flowDataTable OBJECT-TYPE
SYNTAX SEQUENCE OF FlowDataEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The list of all flows being measured."
::= { flowData 1 }
flowDataEntry OBJECT-TYPE
SYNTAX FlowDataEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The flow data record for a particular flow."
INDEX { flowDataTimeMark, flowDataIndex }
::= { flowDataTable 1 }
FlowDataEntry ::= SEQUENCE {
flowDataIndex Integer32,
flowDataTimeMark TimeFilter,
flowDataStatus INTEGER,
flowDataSourceInterface Integer32,
flowDataSourceAdjacentType AddressType,
flowDataSourceAdjacentAddress AdjacentAddress,
flowDataSourceAdjacentMask AdjacentAddress,
flowDataSourcePeerType AddressType,
flowDataSourcePeerAddress PeerAddress,
flowDataSourcePeerMask PeerAddress,
flowDataSourceTransType INTEGER,
flowDataSourceTransAddress TransportAddress,
flowDataSourceTransMask TransportAddress,
flowDataDestInterface Integer32,
flowDataDestAdjacentType AddressType,
flowDataDestAdjacentAddress AdjacentAddress,
flowDataDestAdjacentMask AdjacentAddress,
Brownlee Experimental [Page 20]
RFC 2064 Meter MIB January 1997
flowDataDestPeerType AddressType,
flowDataDestPeerAddress PeerAddress,
flowDataDestPeerMask PeerAddress,
flowDataDestTransType INTEGER,
flowDataDestTransAddress TransportAddress,
flowDataDestTransMask TransportAddress,
flowDataPDUScale INTEGER,
flowDataOctetScale INTEGER,
flowDataRuleSet INTEGER,
flowDataToOctets Counter32, -- Source->Dest
flowDataToPDUs Counter32,
flowDataFromOctets Counter32, -- Dest->Source
flowDataFromPDUs Counter32,
flowDataFirstTime TimeTicks, -- Activity times
flowDataLastActiveTime TimeTicks,
flowDataSourceSubscriberID OCTET STRING,
flowDataDestSubscriberID OCTET STRING,
flowDataSessionID OCTET STRING,
flowDataSourceClass INTEGER,
flowDataDestClass INTEGER,
flowDataClass INTEGER,
flowDataSourceKind INTEGER,
flowDataDestKind INTEGER,
flowDataKind INTEGER
}
flowDataIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of this flow data record's index within the meter's
flow table."
::= { flowDataEntry 1 }
flowDataTimeMark OBJECT-TYPE
SYNTAX TimeFilter
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A TimeFilter for this entry. Allows GetNext and GetBulk
to find flow table rows which have changed since a specified
value of sysUptime."
Brownlee Experimental [Page 21]
RFC 2064 Meter MIB January 1997
::= { flowDataEntry 2 }
flowDataStatus OBJECT-TYPE
SYNTAX INTEGER { inactive(1), current(2), idle(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of this flow data record."
::= { flowDataEntry 3 }
flowDataSourceInterface OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of the interface associated with the source address
for this flow. It's value is one of those contained in the
ifIndex field of the meter's interfaces table."
::= { flowDataEntry 4 }
flowDataSourceAdjacentType OBJECT-TYPE
SYNTAX AddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Adjacent address type of the source for this flow. If
accounting is being performed at the network level the
adjacent address will probably be an 802 MAC address, and
the adjacent address type will indicate the medium type."
::= { flowDataEntry 5 }
flowDataSourceAdjacentAddress OBJECT-TYPE
SYNTAX AdjacentAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Address of the adjacent device on the path for the source
for this flow."
::= { flowDataEntry 6 }
flowDataSourceAdjacentMask OBJECT-TYPE
SYNTAX AdjacentAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1-bits in this mask indicate which bits must match when
comparing the adjacent source address for this flow."
::= { flowDataEntry 7 }
Brownlee Experimental [Page 22]
RFC 2064 Meter MIB January 1997
flowDataSourcePeerType OBJECT-TYPE
SYNTAX AddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Peer address type of the source for this flow."
::= { flowDataEntry 8 }
flowDataSourcePeerAddress OBJECT-TYPE
SYNTAX PeerAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Address of the peer device for the source of this flow."
::= { flowDataEntry 9 }
flowDataSourcePeerMask OBJECT-TYPE
SYNTAX PeerAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1-bits in this mask indicate which bits must match when
comparing the source peer address for this flow."
::= { flowDataEntry 10 }
flowDataSourceTransType OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transport address type of the source for this flow. The
value of this attribute will depend on the peer address type."
::= { flowDataEntry 11 }
flowDataSourceTransAddress OBJECT-TYPE
SYNTAX TransportAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transport address for the source of this flow."
::= { flowDataEntry 12 }
flowDataSourceTransMask OBJECT-TYPE
SYNTAX TransportAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1-bits in this mask indicate which bits must match when
Brownlee Experimental [Page 23]
RFC 2064 Meter MIB January 1997
comparing the transport source address for this flow."
::= { flowDataEntry 13 }
flowDataDestInterface OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of the interface associated with the dest address for
this flow. This value is one of the values contained in the
ifIndex field of the interfaces table."
::= { flowDataEntry 14 }
flowDataDestAdjacentType OBJECT-TYPE
SYNTAX AddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Adjacent address type of the destination for this flow."
::= { flowDataEntry 15 }
flowDataDestAdjacentAddress OBJECT-TYPE
SYNTAX AdjacentAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Address of the adjacent device on the path for the
destination for this flow."
::= { flowDataEntry 16 }
flowDataDestAdjacentMask OBJECT-TYPE
SYNTAX AdjacentAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1-bits in this mask indicate which bits must match when
comparing the adjacent dest address for this flow."
::= { flowDataEntry 17 }
flowDataDestPeerType OBJECT-TYPE
SYNTAX AddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Peer address type of the destination for this flow."
::= { flowDataEntry 18 }
flowDataDestPeerAddress OBJECT-TYPE
Brownlee Experimental [Page 24]
RFC 2064 Meter MIB January 1997
SYNTAX PeerAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Address of the peer device for the destination of this flow."
::= { flowDataEntry 19 }
flowDataDestPeerMask OBJECT-TYPE
SYNTAX PeerAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1-bits in this mask indicate which bits must match when
comparing the dest peer type for this flow."
::= { flowDataEntry 20 }
flowDataDestTransType OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transport address type of the destination for this flow. The
value of this attribute will depend on the peer address type."
::= { flowDataEntry 21 }
flowDataDestTransAddress OBJECT-TYPE
SYNTAX TransportAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transport address for the destination of this flow."
::= { flowDataEntry 22 }
flowDataDestTransMask OBJECT-TYPE
SYNTAX TransportAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"1-bits in this mask indicate which bits must match when
comparing the transport destination address for this flow."
::= { flowDataEntry 23 }
flowDataPDUScale OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The scale factor applied to this particular flow. Indicates
Brownlee Experimental [Page 25]
RFC 2064 Meter MIB January 1997
the number of bits the PDU counter values should be moved left
to obtain the actual values."
::= { flowDataEntry 24 }
flowDataOctetScale OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The scale factor applied to this particular flow. Indicates
the number of bits the octet counter values should be moved
left to obtain the actual values."
::= { flowDataEntry 25 }
flowDataRuleSet OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The RuleSet number of the rule set which created this flow."
::= { flowDataEntry 26 }
flowDataToOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of octets flowing from source to dest address and
being delivered to the protocol level being metered. In the
case of IP this would count the number of octets delivered to
the IP level."
::= { flowDataEntry 27 }
flowDataToPDUs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of protocol packets flowing from source to dest
address and being delivered to the protocol level being
metered. In the case of IP, for example, this would count the
IP packets delivered to the IP protocol level."
::= { flowDataEntry 28 }
flowDataFromOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
Brownlee Experimental [Page 26]
RFC 2064 Meter MIB January 1997
DESCRIPTION
"The count of octets flowing from dest to source address and
being delivered to the protocol level being metered."
::= { flowDataEntry 29 }
flowDataFromPDUs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of protocol packets flowing from dest to source
address and being delivered to the protocol level being
metered. In the case of IP, for example, this would count
the IP packets delivered to the IP protocol level."
::= { flowDataEntry 30 }
flowDataFirstTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time at which this flow was first entered in the table"
::= { flowDataEntry 31 }
flowDataLastActiveTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last time this flow had activity, i.e. the time of
arrival of the most recent PDU belonging to this flow."
::= { flowDataEntry 32 }
flowDataSourceSubscriberID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Subscriber ID associated with the source address for this
flow."
::= { flowDataEntry 33 }
flowDataDestSubscriberID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Subscriber ID associated with the dest address for this
Brownlee Experimental [Page 27]
RFC 2064 Meter MIB January 1997
flow."
::= { flowDataEntry 34 }
flowDataSessionID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4..10))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Session ID for this flow. Such an ID might be allocated
by a network access server to distinguish a series of sessions
between the same pair of addresses, which would otherwise
appear to be parts of the same accounting flow."
::= { flowDataEntry 35 }
flowDataSourceClass OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Source class for this flow. Determined by the rules, set by
a PushRule action when this flow was entered in the table."
::= { flowDataEntry 36 }
flowDataDestClass OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Destination class for this flow. Determined by the rules, set
by a PushRule action when this flow was entered in the table."
::= { flowDataEntry 37 }
flowDataClass OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Class for this flow. Determined by the rules, set by a
PushRule action when this flow was entered in the table."
::= { flowDataEntry 38 }
flowDataSourceKind OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Source kind for this flow. Determined by the rules, set by
a PushRule action when this flow was entered in the table."
Brownlee Experimental [Page 28]
RFC 2064 Meter MIB January 1997
::= { flowDataEntry 39 }
flowDataDestKind OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Destination kind for this flow. Determined by the rules, set
by a PushRule action when this flow was entered in the table."
::= { flowDataEntry 40 }
flowDataKind OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Class for this flow. Determined by the rules, set by a
PushRule action when this flow was entered in the table."
::= { flowDataEntry 41 }
--
-- The Activity Column Table
--
flowColumnActivityTable OBJECT-TYPE
SYNTAX SEQUENCE OF FlowColumnActivityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index into the Flow Table. Allows a meter reader to retrieve
a list containing the flow table indeces of flows which were
last active at or after a given time, together with the values
of a specified attribute for each such flow."
::= { flowData 2 }
flowColumnActivityEntry OBJECT-TYPE
SYNTAX FlowColumnActivityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Column Activity Entry for a particular attribute,
activity time and flow."
INDEX { flowColumnActivityAttribute, flowColumnActivityTime,
flowColumnActivityIndex }
::= { flowColumnActivityTable 1 }
FlowColumnActivityEntry ::= SEQUENCE {
Brownlee Experimental [Page 29]
RFC 2064 Meter MIB January 1997
flowColumnActivityAttribute FlowAttributeNumber,
flowColumnActivityTime TimeFilter,
flowColumnActivityIndex Integer32,
flowColumnActivityData OCTET STRING
}
flowColumnActivityAttribute OBJECT-TYPE
SYNTAX FlowAttributeNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the attribute for which values are required from
active flows."
::= { flowColumnActivityEntry 1 }
flowColumnActivityTime OBJECT-TYPE
SYNTAX TimeFilter
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable is a copy of flowDataLastActiveTime in the
flow data record identified by the flowColumnActivityIndex
value of this flowColumnActivityTable entry."
::= { flowColumnActivityEntry 2 }
flowColumnActivityIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of a flow table entry which was active at or after
a specified flowColumnActivityTime."
::= { flowColumnActivityEntry 3 }
flowColumnActivityData OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (3..1000))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Collection of attribute data for flows active after
flowColumnActivityTime. Within the OCTET STRING is a
sequence of { flow index, attribute value } pairs, one for
each active flow. The end of the sequence is marked by a
flow index value of 0, indicating that there are no more
rows in this column.
The format of objects inside flowColumnFlowData is as follows.
All numbers are unsigned. Numbers and strings appear with
Brownlee Experimental [Page 30]
RFC 2064 Meter MIB January 1997
their high-order bytes leading. Numbers are fixed size, as
specified by their SYNTAX in the flow table (above), i.e. one
octet for flowAddressType and small constants, and four octets
for Counter and Timeticks. Strings are variable-length, with
the length given in a single leading octet.
The following is an attempt at an ASN.1 definition of
flowColumnActivityData:
flowColumnActivityData ::= SEQUENCE flowRowItemEntry
flowRowItemEntry ::= SEQUENCE {
flowRowNumber INTEGER (1..65535),
-- 0 indicates the end of this column
flowDataValue flowDataType -- Choice depends on attribute
}
flowDataType ::= CHOICE {
flowByteValue INTEGER (1..255),
flowShortValue INTEGER (1..65535),
flowLongValue Integer32,
flowStringValue OCTET STRING -- Length (n) in first byte,
-- n+1 bytes total length, trailing zeroes truncated
}"
::= { flowColumnActivityEntry 4 }
--
-- The Rule Table
--
-- This is an array of rule tables; the one in use is selected by
-- CurrentRuleSet. To change the rule set the manager chooses a set
-- number which is not in use, downloads the new rule set there, then
-- writes the new set number into CurrentRuleSet. Rule set 1 is the
-- default rule set, used by the meter on start-up. Several rule sets
-- can be held in a meter so that the manager can change the rules
-- easily, for example with time of day. Note that a manager may
-- not change the default rule set, nor the rules in its current rule
-- set! See the 'Traffic Flow Measurement: Architecture' document [9]
-- for details of rules and how they are used.
flowRuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF FlowRuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains all the rule sets which may be used by the meter."
::= { flowRules 1 }
Brownlee Experimental [Page 31]
RFC 2064 Meter MIB January 1997
flowRuleEntry OBJECT-TYPE
SYNTAX FlowRuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The rule record itself."
INDEX { flowRuleSet, flowRuleIndex }
::= { flowRuleTable 1 }
FlowRuleEntry ::= SEQUENCE {
flowRuleSet INTEGER,
flowRuleIndex INTEGER,
flowRuleSelector RuleAttributeNumber,
flowRuleMask RuleAddress,
flowRuleMatchedValue RuleAddress,
flowRuleAction ActionNumber,
flowRuleParameter Integer32
}
flowRuleSet OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Selects a rule set from the array of rule sets."
::= { flowRuleEntry 1 }
flowRuleIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index into the Rule table. N.B: These values will
often be consecutive, given the fall-through semantics of
processing the table."
::= { flowRuleEntry 2 }
flowRuleSelector OBJECT-TYPE
SYNTAX RuleAttributeNumber
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the attribute to be matched.
null(0) is a special case; null rules always succeed.
v1(51), v2(52), v3(53), v4(54) and v5(55) select meter
variables, each of which can hold the name (i.e. selector
Brownlee Experimental [Page 32]
RFC 2064 Meter MIB January 1997
value) of an address attribute. When one of these is used
as a selector, its value specifies the attribute to be
tested. Variable values are set by an Assign action."
::= { flowRuleEntry 3 }
flowRuleMask OBJECT-TYPE
SYNTAX RuleAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The initial mask used to compute the desired value. If the
mask is zero the rule's test will always succeed."
::= { flowRuleEntry 4 }
flowRuleMatchedValue OBJECT-TYPE
SYNTAX RuleAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The resulting value to be matched for equality.
Specifically, if the attribute chosen by the flowRuleSelector
logically ANDed with the mask specified by the flowRuleMask
equals the value specified in the flowRuleMatchedValue, then
continue processing the table entry based on the action
specified by the flowRuleAction entry. Otherwise, proceed to
the next entry in the rule table."
::= { flowRuleEntry 5 }
flowRuleAction OBJECT-TYPE
SYNTAX ActionNumber
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The action to be taken if this rule's test succeeds, or if
the meter's 'test' flag is off. Actions are opcodes for the
meter's Packet Matching Engine; details are given in the
'Traffic Flow Measurement: Architecture' document [9]."
::= { flowRuleEntry 6 }
flowRuleParameter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A parameter value providing extra information for the
rule's action."
::= { flowRuleEntry 7 }
Brownlee Experimental [Page 33]
RFC 2064 Meter MIB January 1997
--
-- Traffic Flow Meter conformance statement
--
flowMIBCompliances
OBJECT IDENTIFIER ::= { flowMIBConformance 1 }
flowMIBGroups
OBJECT IDENTIFIER ::= { flowMIBConformance 2 }
flowControlGroup OBJECT-GROUP
OBJECTS {
flowRuleInfoSize, flowRuleInfoOwner,
flowRuleInfoTimeStamp, flowRuleInfoStatus,
flowInterfaceRate,
flowInterfaceLostPackets,
flowReaderTimeout, flowReaderOwner,
flowReaderLastTime, flowReaderPreviousTime,
flowReaderStatus,
flowManagerCurrentRuleSet, flowManagerStandbyRuleSet,
flowManagerHighWaterMark,
flowManagerOwner, flowManagerTimeStamp,
flowManagerStatus,
flowFloodMark,
flowInactivityTimeout,
flowActiveFlows,
flowMaxFlows }
STATUS current
DESCRIPTION
"The control group defines objects which are used to control
an accounting meter."
::= {flowMIBGroups 1 }
flowDataTableGroup OBJECT-GROUP
OBJECTS {
flowDataIndex,
flowDataStatus,
flowDataSourceInterface,
flowDataSourceAdjacentType,
flowDataSourceAdjacentAddress, flowDataSourceAdjacentMask,
flowDataSourcePeerType,
flowDataSourcePeerAddress, flowDataSourcePeerMask,
flowDataSourceTransType,
flowDataSourceTransAddress, flowDataSourceTransMask,
flowDataDestInterface,
flowDataDestAdjacentType,
flowDataDestAdjacentAddress, flowDataDestAdjacentMask,
flowDataDestPeerType,
Brownlee Experimental [Page 34]
RFC 2064 Meter MIB January 1997
flowDataDestPeerAddress, flowDataDestPeerMask,
flowDataDestTransType,
flowDataDestTransAddress, flowDataDestTransMask,
flowDataRuleSet,
flowDataToOctets, flowDataToPDUs,
flowDataFromOctets, flowDataFromPDUs,
flowDataFirstTime, flowDataLastActiveTime,
flowDataSourceClass, flowDataDestClass, flowDataClass,
flowDataSourceKind, flowDataDestKind, flowDataKind
}
STATUS current
DESCRIPTION
"The flow table group defines objects which provide the
structure for the rule table, including the creation time
and activity time indexes into it. In addition it defines
objects which provide a base set of flow attributes for the
adjacent, peer and transport layers, together with a flow's
counters and times. Finally it defines a flow's class and
kind attributes, which are set by rule actions."
::= {flowMIBGroups 2 }
flowDataScaleGroup OBJECT-GROUP
OBJECTS {
flowManagerCounterWrap,
flowDataPDUScale, flowDataOctetScale
}
STATUS current
DESCRIPTION
"The flow scale group defines objects which specify scale
factors for counters."
::= {flowMIBGroups 3 }
flowDataSubscriberGroup OBJECT-GROUP
OBJECTS {
flowDataSourceSubscriberID, flowDataDestSubscriberID,
flowDataSessionID
}
STATUS current
DESCRIPTION
"The flow subscriber group defines objects which may be used
to identify the end point(s) of a flow."
::= {flowMIBGroups 4 }
flowDataColumnTableGroup OBJECT-GROUP
OBJECTS {
flowColumnActivityAttribute,
flowColumnActivityTime,
flowColumnActivityIndex,
Brownlee Experimental [Page 35]
RFC 2064 Meter MIB January 1997
flowColumnActivityData
}
STATUS current
DESCRIPTION
"The flow column table group defines objects which can be used
to collect part of a column of attribute values from the flow
table."
::= {flowMIBGroups 5 }
flowRuleTableGroup OBJECT-GROUP
OBJECTS {
flowRuleSelector,
flowRuleMask, flowRuleMatchedValue,
flowRuleAction, flowRuleParameter
}
STATUS current
DESCRIPTION
"The rule table group defines objects which hold the set(s)
of rules specifying which traffic flows are to be accounted
for."
::= {flowMIBGroups 6 }
flowMIBCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for a Traffic Flow Meter."
MODULE
MANDATORY-GROUPS {
flowControlGroup,
flowDataTableGroup,
flowRuleTableGroup
}
::= { flowMIBCompliances 1 }
END
Brownlee Experimental [Page 36]
RFC 2064 Meter MIB January 1997
5 Acknowledgements
This document was initially produced under the auspices of the IETF's
Accounting Working Group with assistance from SNMP and SAAG working
groups. Particular thanks are due to Jim Barnes, Sig Handelman and
Stephen Stibler for their support and their assistance with checking
the MIB.
6 References
[1] McCloghrie, K., and M. Rose, Editors, "Management Information
Base for Network Management of TCP/IP-based internets," STD 17, RFC
1213, Performance Systems International, March 1991.
[2] Case J., McCloghrie K., Rose M., and S. Waldbusser, "Structure of
Management Information for version 2 of the Simple Network
Managemenet Protocol," RFC 1902, SNMP Research Inc., Hughes LAN
Systems, Dover Beach Consulting, Carnegie Mellon University, April
1993.
[3] Case J., McCloghrie, K., Rose, M., and S. Waldbusser, "Textual
Conventions for version 2 of the Simple Network Managemenet Protocol
SNMPv2", RFC 1903, SNMP Research Inc., Hughes LAN Systems, Dover
Beach Consulting, Carnegie Mellon University, April 1993.
[4] Case, J., McCloghrie, K., Rose, M., and S. Waldbusser,
"Conformance Statements for version 2 of the Simple Network
Managemenet Protocol (SNMPv2)," RFC 1904, SNMP Research Inc., Hughes
LAN Systems, Dover Beach Consulting, Carnegie Mellon University,
April 1993.
[5] Case, J., McCloghrie, K., Rose, M., and S. Waldbusser,
"Coexistence between version 1 and version 2 of the Internet-standard
Network Management Framework," RFC 1908, SNMP Research Inc., Hughes
LAN Systems, Dover Beach Consulting, Carnegie Mellon University,
April 1993.
[6] Information processing systems - Open Systems Interconnection -
Specification of Abstract Syntax Notation One (ASN.1), International
Organization for Standardization, International Standard 8824,
December 1987.
[7] Information processing systems - Open Systems Interconnection -
Specification of Basic Encoding Rules for Abstract Notation One
(ASN.1), International Organization for Standardization,
International Standard 8825, December 1987.
Brownlee Experimental [Page 37]
RFC 2064 Meter MIB January 1997
[8] Mills, C., Hirsch, G. and G. Ruth, "Internet Accounting
Background," RFC 1272, Bolt Beranek and Newman Inc., Meridian
Technology Corporation, November 1991.
[9] Brownlee, N., Mills, C., and G. Ruth, "Traffic Flow Measurement:
Architecture", RFC 2063, The University of Auckland, Bolt Beranek and
Newman Inc., GTE Laboratories, Inc, January 1997.
[10] Waldbusser, S., "Remote Network Monitoring Management
Information Base, Version 2," Work in Progress.
[11] Reynolds, J., and J, Postel, "Assigned Numbers," STD 2, RFC
1700, ISI, October 1994.
[12] Case, J., "FDDI Management Information Base," RFC 1285, SNMP
Research Incorporated, January 1992.
7 Security Considerations
Security issues are not discussed in this document.
8 Author's Address
Nevil Brownlee
Information Technology Systems & Services
The University of Auckland
Phone: +64 9 373 7599 x8941
EMail: n.brownlee @auckland.ac.nz